IDEXX Catalyst One®
A brand new experience in animal clinical chemistry testing, wishing you a helping hand on your research journey
● 35 clinical chemistry test items
● 39 different animal-specific reference ranges
● Dry technology results are more accurateAll-rounder
One machine with multiple uses, providing up to 35 blood biochemical index results (including 6 calculated values), including liver function, kidney function, blood sugar, blood lipids, electrolytes, to meet the needs of animal experiments, preclinical drug research, pharmacology and toxicology and other scientific research laboratories for animal blood biochemical index testing
Efficient
Pre-installed clamps and single pieces for quick loading, all kinds of testing items can be completed with one click, and the results can be obtained in just 8 minutes
major
Micro blood analysis (10ul), suitable for rats, mice and other rodents experimental animal dedicated software, built-in 39 different species and ages of animals dedicated normal value range
rest assured
Professional quality, designed with a mean trouble-free time of up to 60 months Worry-free after-sales service, providing EMA extended warranty service and 400 free technical support hotlines Unique dry chemical technology to keep interfering substances away from animal blood samples Interfering substance categories

Research reports show that more than 70% of animal blood samples contain different interfering substances. In other words, if the influence of interfering substances cannot be effectively resolved, the probability of obtaining accurate test results is less than 30%.

Bottom light source detection technology to eliminate the impact of interfering substances on the results
More accurate test results

Rapid, instant testing
■ Testing speed: Each test takes only 8 minutes. Each batch can hold up to 18 test pieces.
■ Built-in high-speed centrifuge, whole blood samples can be loaded onto the machine without pre-treatment, saving a lot of time.Flexible project selection——combine as you like without waste


■ Integrates liver function, kidney function, blood sugar, blood lipids, and electrolytes;
■ You can choose from pre-installed kits or single reagent tablets, which can be freely combined to meet the needs of different research directions.Verified for multiple species
Experimental animals: rats, mice, rabbits, monkeys, etc.
Economic animals: pigs, cattle, goats, sheep, etc.
Companion animals: dogs, cats, horses, parrots, etc.
Wild animals: snakes, minks, lizards, turtles, etc.Multiple pre-dilution options - suitable for even small blood samples

■ When the test results exceed the linear range of the analyzer or there are interfering substances affecting the test results, we need to dilute the sample before analysis.
■ Provides two options: automatic dilution and manual dilution. Samples can be diluted by 2, 4, or 10 times. The final calculation result will be automatically multiplied by the dilution factor, eliminating the need for manual calculation.Three-step operation - never picky about operators

Performance Indicators
Technical Principle Multi-layer membrane dry chemical technology, containing a special filter layer to eliminate the influence of interfering substances on chemical reactions
Detection indicators
(35 items) Liver and kidney function: ALKP, ALT, AST, GGT, LDH, NH3, TBIL, GLOB, ALB/GLOB, ALB, TP, BUN, CREA, UPRO, UCREA, URIC, BUN/CREA, UPRO/UCREA, Osmolality Blood glucose and lipids: CHOL, FRU, GLU, TRIG Myocardial enzymes and pancreas: CK, AMYL, LIPA Electrolytes: Ca, Mg, PHOS, Na, K, Cl, Na/K, LACT, PHBR
Detection speed: 8 minutes/batch (from automatic centrifugation to report printing)
Sample volume: 10ul/test item (serum/plasma), 700ul (whole blood)
Applicable species Provide reference value ranges for 39 animals including rats, mice, rabbits, monkeys, sheep, pigs, cattle, snakes, birds, etc.
Data storage is stored in the IDEXX Vetlab laboratory management system
The operation interface is displayed in Chinese and English, with a color touch screen
No need for cleaning for daily maintenance, just internal cleaning once a month is sufficient
Quality control is performed using VetTrol’s special quality control products, and it is recommended to be performed once a month
Data output can be connected to an external printer to print the test report on A4 paper
Clear and easy-to-understand test reports

References:
SCI authoritative journal literature citation
1. [IF:7.782] Mouse model of chronic and binge ethanol feeding (the NIAAA model)
Journal published:Nature Protocols. 2013 Mar; 8(3):627-37.
2. [IF:13.926 ] Monoacylglycerol Lipase Controls Endocannabinoid and Eicosanoid signaling and Hepatic Injury in Mice
Journal published:Gastroenterology. 2013 Apr; 144(4):808-817
3. [IF:3.737] CFTR dysfunction predisposes to fibrotic liver disease in a murine model
Journal published:Am J Physiol Gastrointest Liver Physiol. 2012 Aug 15; 303(4):G474-81.
4. [IF:28.054] Lethal inflammasome activation by a multidrug-resistant pathobiont upon antibiotic disruption of the microbiota
Journal published:Nature Medicine. 2012 May; 18(5):799-806.
5. [IF:23.893] Double antiangiogenic protein, DAAP, targeting VEGF-A and angiopoietins in tumor angiogenesis, metastasis, and vascular leakage.
Journal: Cancer Cell. 2010 Aug 9; 18(2):171-84.User list:
Animal Platform of the State Key Laboratory of Cardiovascular Diseases, Fuwai Hospital
Institute of Zoology, Chinese Academy of Sciences
School of Public Health, China Medical University
Harbin Veterinary Research Institute, Chinese Academy of Agricultural Sciences (P4 Laboratory)
Xiuzhen Pharmaceutical
Peking University Health Science Center State Key Laboratory of Cardiovascular Diseases
Southern Medical University
China Agricultural University
Product inquiry
Looking forward to your message !