Large Animal PET/CT MadicLab

Key words:

Classification:

Service Hotline:

  • Product Description
  •  

    Submillimeter large animal PET/CT for whole-body imaging of mice, rats, rabbits and brain imaging of primates

     

    ► "High sensitivity technology" uses capsule-shaped PET detectors with uniform sensitivity in the entire field of view
    ►Customizable overall 1 meter large animal PET
    ► Second-level 4D PET imaging, imaging speed can reach 0.2 seconds/frame
    ►List-mode acquisition and GPU-accelerated reconstruction
    ►The detector uses LYSO scintillation crystal and SiPM array
    ►Non-invasive imaging technology, repeated studies and continuous experiments on the same animal, avoid individual differences and significantly reduce the number of experimental animals.
    ►Dynamically obtain kinetic data in seconds and quickly image physiological and pharmacological processes.
    ►Shorten the time it takes for new compounds to enter the clinic.

     

     

    Basic biological research: research on biological activities and biological characteristics

    Drug development: drug screening, preclinical drug research, drug efficacy evaluation

    Disease research: especially in the fields of cancer, cardiovascular disease, diabetes, neuroscience, and genetic diseases

    Research on highly specific molecular tracers: such as PET tracers, peptides, monoclonal antibodies and other molecular probes.

    It can realize the imaging of animals of different sizes from rabbits to monkeys, with a large axial field of view and high PET resolution. Most importantly, through dynamic images, it is possible to more intuitively observe the distribution of the drug in the blood and body of the observed animal every second from the beginning of injection, thereby providing comprehensive image and data support for drug absorption, distribution, metabolism, etc., and analyzing the physiological and biochemical processes in living tissues, so as to make judgments on drug dosage, site of action, possible toxic and side effects, etc.

     

    Technical parameters:

    ● Crystal size is 0.94x0.94x12mm
    ● Axial field of view 90mm, lateral field of view 160mm, scanning aperture 220mm

     

    Aperture up to 0.7mm

     

     

     

    Case Showcase

     

      

    Rabbit with weight of 181g, 18F-FDG                NR_iter15_sub_1 4-bed bed

     

      

     

    330g rabbit ear vein injection of 18F-FDG 1.03mCi 60 minutes later, each bed collected 15 minutes, a total of 3 beds / 195g rabbit ear vein injection of 18F-FDG 190uci 35 minutes later, a single bed collected 2 hours

     

     

     

     

Product inquiry